PMSF-6 units (without built-in compressor) and PMSF-6-K (with built-in compressor) are designed for local removal and purification of air from aerosols and dust particles generated during welding, cleaning, grinding of metals, as well as similar types of processing of various materials.

Operation principle
The principle of operation of the filters is based on the local capture of polluted air, the mechanical cleaning of air from harmful substances and the return of purified air to the production room.
Air recirculation reduces energy costs for the general ventilation of rooms, heating, maintenance of the filter itself and protects the workers of the enterprises from the effects of harmful substances released during technological operations.

Working conditions
PMSF-6 filters are designed for continuous operation in enclosed spaces under the following conditions:
● mode S1 according to GOST IEC 60034-1-2014;
● ambient temperature from plus 5 to plus 45 °С;
● relative humidity no more than 80% at plus 25 °С;
● the temperature of the transported airstream should not exceed plus 80 °С;
● the air stream must be non-explosive, must not contain aggressive vapors and gases, sticky and fibrous dust, as well as particles and materials prone to smoldering and spontaneous combustion.

 

● High performance up to 2400 m³ / h with low energy consumption – 1.5 kW;
● Compact body – 775x888x1520 mm;
● Low noise level – 75 dBA;
● Horizontal flat-oval cartridges (2 pcs.) With high filtration class;
● Intelligent automatic cleaning system with ΔP function (extends cartridge life, reduces power consumption and compressed air consumption);
● Light and sound alarm of maximum contamination of the cartridge;
● Simple system of pressing and fixing cartridges for easy filter maintenance;
● Possibility of installing two exhaust devices ø160 mm or one ø200 mm or ø160 mm;
● Built-in oil-free compressor (option);
● Activated carbon filter (optional);
● Two-stage spark protection that reduces the risk of fire;
● Outlet of purified air up;
● Filter operation controls are located in the upper part of the housing for the convenience of operating personnel;
● The filter control keys are duplicated on the funnel of the exhaust device;
● Reinforced swivel wheels with locking mechanism to ensure filter maneuverability and ease of operation in confined spaces;
● Convenient pull-out dust collector.

Description
DCSC-M-6
DCSC-M-6-K
Max airflow, m³/h
2400
Power consumption of the filter, kW
2
Filter supply voltage, V / Hz / Phase
230/50/1
Motor power, kW
1.5
Max. compressed air consumption, L/min. free air:
- factory setting (1 pulse/min.)
- manual setting (up to 3 pulse/min.)
45
135
-
Pressure of the supplied compressed air (working), MPa (bar)
0.5 – 0.55
(5.0 – 5.5)
-
Filteration class (DIN EN 779-93)
Filteration class (DIN EN 60335-2-69 )
F9
M
-
Active filtering surface, m²
24 (2x12)
Cartridge Type / Material
Cart-T12 / PTFE membrane
Max. differential pressure ∆P, Pa
1800
Extra cleaning stage
Carbon filter
Noise level, dBA
75
Diameter of the inlet for the pipe, mm
160
Overall dimensions, mm
775х888х1520
Filter weight, kg*
155
185
Degree of protection in accordance with GOST 14254-80
IP54
Mode of operation
continuous
Compressor type
-
oil free
* excluding the mass of the exhaust device

Delivery set:

  • plane-oval cartridge, 12 m² – 2 pcs;
  • protective metal bumper screens – 2 pcs;
  • built-in fan in noise-reduction jacket – 1 pc;
  • power cable with European plug, 5 m – 1 pc;
  • control panel with ΔP-function, light and noise alarm, transformer for BEA extraction arms with light;
  • built-in oil-free air compressor (for DCSC-M-6-K models) – 1 pc;
  • oil-water separator (for DCSC-M-6 models) – 1 pc.
Article №ModelMax
airflow,
m3/h
Filtration
surface,
m2
Filtration
class
Power
consumption,
kW
Weight,
kg
DCSC-M-6 (For one extraction arm with diameter 160 mm)
501116DCSC-M-6-160-T12240024 (2x12)F9Fan- 1.5155
501117DCSC-M-6-160-TC12
501118DCSC-M-6-160-D12
DCSC-M-6 (For two extraction arm with diameter 160 mm)
501119DCSC-M-6-2x160-Т12240024 (2x12)F9Fan- 1.5155
501120DCSC-M-6-2x160-ТC12
501121DCSC-M-6-2x160-D12
DCSC-M-6 (For one extraction arm with diameter 200 mm)
501122DCSC-M-6-200-Т12240024 (2x12)F9Fan- 1.5155
501123DCSC-M-6-200-ТC12
501124DCSC-M-6-200-D12
DCSC-M-6-K (For one extraction arm with diameter 160 mm) with built-in air compressor
501107DCSC-M-6-160-К-Т12240024 (2x12)F9Fan- 1.5
Air compressor - 0.5
185
501108DCSC-M-6-160-К-ТC12
501109DCSC-M-6-160-К-D12
DCSC-M-6-K (For two extraction arm with diameter 160 mm) with built-in air compressor
501110DCSC-M-6-2x160-К-Т12240024 (2x12)F9Fan- 1.5
Air compressor - 0.5
185
501111DCSC-M-6-2x160-К-ТC12
501112DCSC-M-6-2x160-К-D12
DCSC-M-6-K (For one extraction arm with diameter 200 mm) with built-in air compressor
501113DCSC-M-6-200-К-Т12240024 (2x12)F9Fan- 1.5
Air compressor - 0.5
185
501114DCSC-M-6-200-К-ТC12
501115DCSC-M-6-20-К-D12

  1. Control Panel
  2. Filter cover
  3. Prefilter
  4. Filter housing
  5. Cartridge, 2 × 12 m²
  6. Dust collector
  7. Fan housing
  8. Swivel wheel
  9. Swivel wheel with brake
  10. Door
  11. Vent for the vertical outlet of purified air
    (optional – an activated carbon filter is installed under the grate)

Complete set

 ArticleModelDescription
Oval filter cartridge (2 pcs included in delivery set), F9 (GOST R EN 779-2104)



oval filter

600008CART-OV-T12Polyester with PTFE membrane
600009CART-OV-TC12Polyester with PTFE membrane and antistatic coating
6000010CART-OV-D12Polyester

Options
SketchArticleModelDescription
Prefilter6673FF-006Mesh washable prefilter, G3 (GOST R EN 779-2014)
carbon filter6011CF-006Activated carbon filter
Filter for air cleaning from odors and toxic gases
Cartridge predusting means18079Preco-NCartridge predusting means, 1 kg (for cartridges CART-OV-D12).
Consumption 1 kg for 24 m 2
7331Preco-N

Usually used with

Have a question? Contact us We will provide full information and find a solution that suits your process needs
Contact our Industrial Air Filtration Expert

    By clicking submit, I acknowledge receipt of the sovplym.in Privacy Policy

    Contacts


    Address

    Arrisa Avenue, Unit #15, Office No. 303, 3rd Floor, Kolte Patil Downtown, Kharadi, Pune-411014, India

    Help & support

      By clicking submit, I acknowledge receipt of the sovplym.in Privacy Policy