Pre-separator is intended for removal of mist and vapors of oil and emulsion, used for greasing and cooling in metal processing equipment, from air. Main purpose of the installation – significant decreasing of concentration of oil mists at the entrance to main filtration module.

It is possible to use it in a non-standard way for precipitation of mists of other liquids, including general water.

Working principle

Polluted air enters inner chamber of pre-separator through the inlet duct and passes through drop catcher, where drops of oil and emulsions are settled, and clean air comes out of the outlet in the pre-separator cover and goes into the ventilation network.
Condensed liquids are collected in the bottom of the casing and drained from the pre-separator via connection pipe.

Advantages

– Equipped with durable cleaning module made of stainless steel
– Efficiency is proved by years of operation in oil and gas industry in a form of columns for drying of associated gases
– Does not require any spares

Working conditions

Pre-separator is designed for long time operation in closed premises at following climatic conditions:
– ambient temperature from 5 to plus 45 °C
– relative humidity not more than 80% at plus 25 °C

 

Name of the parameter of characteristicParameter value
PMT-160-1000
PMT-200-2000
PMT-250-3000
PMT-315-4000
PMT-350-5000
Airflow, m3/h
1000
2000
3000
4000
5000
Diameter of connected ducts, mm
160
200
250
315
350
Max weight, kg
18
28
36
45
57
CodeArticleName
600020PMT1-160-1000Oil mist pre-separator
600021PMT1-200-2000Oil mist pre-separator
600022PMT1-250-3000Oil mist pre-separator
600023PMT1-315-4000Oil mist pre-separator
600024PMT1-355-5000Oil mist pre-separator

Detailed description can be found in the PMT User Manual (see “Documents” tab)

Floor support for pre-separator PS (with fasteners)
Intended for installation of the pre-separator on the floor. Supplied with connection joint for mounting of pre-separator.

Pre-separator bracket BS (with fasteners)
Intended for installation on the pre-separator on the wall. Supplied with connection joint for mounting of pre-separator.

Mounting column for pre-separator MCP (with fasteners)

Attention! MCP column is ordered as an addition to BS bracket. Used for installation of pre-separator on the floor at significant height. Supplied with connection joint for mounting of pre-separator.

CodeArticleName
600025PS1Pre-separator’s support
600026PS3Pre-separator’s support
600027BS1Pre-separator’s bracket, pre-assembled
600028BS3Pre-separator’s bracket, pre-assembled
600029MCP1Pre-separator’s mounting column

 

1. Pre-separator’s body
2. Cover
3. Drop catcher
4. Connection pipe ½” x 12
5. Gasket
6. Nut ½”

Picture. Dimensions of PMT

Articled, mmD, mmD1, mmD2, mml1, mml2, mml3, mmL, mmh, mmH, mmM, mm
PMT-160-1000159350385250590250170840237430M8
PMT-200-2000199500535250670300190970322605M8
PMT-250-30002496006354007703502151120372705M10
PMT-315-40003147007355008904002401290422805M10
PMT-350-50003498008355009705002601470472905M10

Have a question? Contact us We will provide full information and find a solution that suits your process needs
Contact our Industrial Air Filtration Expert

    By clicking submit, I acknowledge receipt of the sovplym.in Privacy Policy

    Contacts


    Address

    Arrisa Avenue, Unit #15, Office No. 303, 3rd Floor, Kolte Patil Downtown, Kharadi, Pune-411014, India

    Help & support

      By clicking submit, I acknowledge receipt of the sovplym.in Privacy Policy